Detector with Integral Electronics
Ronan's integral point level switch houses the Geiger-Mueller Tube Detector and associated electronics. The detector is powered from a 115/230 VAC 50/60 Hz supply and provides a DPDT contact output rated at 13 amps 115 VAC/non-inductive. The housing is explosion proof suitable for Cl. I, Div. 1, Gr. A, B, C & D and Cl. II, Div. 1, Gr. E, F, & G.
|
|
Point Level Switch
|
Detector with Remote Electronics
For applications where high temperatures or hazardous conditions hinder access to the detector, the remotely mounted electronics are recommended. In these cases the use of the Geiger-Mueller Tube Detector the Scintillation Detector is used in conjunction with a remote mounted electronics module. Both detectors are suitable for location in explosion proof areas rated Cl. I, Div. 1, Gr. A, B, C & D and Cl. II, Div 1, Gr. E, F, & G.
|
|
|
|
GM Tube Detector
|
Scintillation Detector/Housing
|
Remote Electronics
|
The remote electronics may mount in a single point surface mount chassis, multipoint surface mount chassis or multipoint rack mount chassis. Power requirements are 115/230 VAC while the output is a DPDT set of contacts rated at 3 amps/115 VAC
|
|